Images are representations only.

Series GSTA/GSTC Carbon Monoxide/Nitrogen Dioxide Gas Transmitter

Brand: Dwyer Instruments, LLC

Free Shipping on Orders Over $362.33 USD

The Series GSTA and GSTC Carbon Monoxide/Nitrogen Dioxide Gas Transmitters monitor gas concentrations in mechanical rooms, underground parking garages and loading docks.

The carbon monoxide transmitter is used to measure the exhaust of gasoline engines, while the nitrogen dioxide transmitter is used for diesel engines.

The Series GSTA features field selectable current and voltage outputs while the Series GSTC features BACnet or Modbus® communication protocol, allowing gas sensing solutions that can be used with almost any building management controller.
Features
  • Add optional integral LCD display by adding -LCD to end of model number (Example: GSTA-C-LCD)
  • Industrial grade replaceable CO or NO2 sensors
  • Field selectable current or voltage output on GSTA models
  • Service display tool for set-up and calibration of models without a LCD
show more
The Series GSTA and GSTC Carbon Monoxide/Nitrogen Dioxide Gas Transmitters monitor gas concentrations in mechanical rooms, underground parking garages and loading docks.

The carbon monoxide transmitter is used to measure the exhaust of gasoline engines, while the nitrogen dioxide transmitter is used for diesel engines.

The Series GSTA features field selectable current and voltage outputs while the Series GSTC features BACnet or Modbus® communication protocol, allowing gas sensing solutions that can be used with almost any building management controller.
Features
  • Add optional integral LCD display by adding -LCD to end of model number (Example: GSTA-C-LCD)
  • Industrial grade replaceable CO or NO2 sensors
  • Field selectable current or voltage output on GSTA models
  • Service display tool for set-up and calibration of models without a LCD

Specifications

Accuracy

  • 2 % of Reading
  • 3 % at the Time of Calibration

Ambient Temperature Range

  • -20° to 50° C (-4° to 122° F)

Approvals & Certifications

  • CE

Display

  • LCD Display

Electrical Connectors

  • Knocks Out for Conduit Fitting
  • Removable Terminal Block

Enclosure, Body Material

  • UV Resistant Glass-Filled Polycarbonate

Flow Rate

  • 0 to 500 ppm

Humidity

  • 0 to 99 % Relative Humidity
  • 15 to 90 % Relative Humidity

Mounting

  • Duct Mount
  • Wall Mounted

Output

  • 0-10 V at 5 mA
  • 0-5 V at 5 mA
  • 1-5 V
  • 2 to 10 V
  • 4-20 mA

Response Time

  • < 45 seconds to 90 % CO

Storage Temperature

  • 0° to 20° C (32° to 68° F)

Supply Voltage

  • 10-35 Vdc
  • 15-29 Vac
  • 15-35 Vdc

Typical Applications

  • Garage or Loading Dock Ventilation
  • Mechanical Room Monitoring